Ventilation element    Roof hood with louvred cap

Thermo Flap

TF-DC-RJ-0,41-450x450-0,1 TF-DC-RJ-0,41-450x450x750-0,1 TF-DC-RJ-0,46-600x600-0,2 TF-DC-00-0,46-600x600x750-0,2 TF-DC-RJ-0,55-800x800-0,39 TF-DC-00-0,55-800x800x750-0,39
Net ventilation aera

0.10 m²

0.10 m²

0.20 m²

0.20 m²

0.39 m²

0.39 m²

Recommended unfinished opening 450 x 450 mm 450 x 450 mm 600 x 600 mm 600 x 600 mm

800 x 800 mm

800 x 800 mm

Base width (B1xH1)

810 x 810 mm

810 x 810 mm

960 x 960 mm

960 x 960 mm

1160 x 1160 mm

1160 x 1160 mm

Ventilation hood dimensions (B2xH2)

595 x 630 mm

595 x 630 mm

745 x 780 mm

745 x 780 mm

950 x 985 mm

950 x 985 mm

Ventilation base height (L1)

500 mm

750 mm

500 mm

750 mm

500 mm

750 mm

Ventilation hood height louvre hat (L2)

332 mm

332 mm

332 mm

332 mm

385 mm

385 mm

Total height (L3)

789 mm

1039 mm

789 mm

1039 mm

842 mm

1092 mm

U-value (tested and certified according to DIN EN ISO 12567-2)

0.41 W/m²K

0.41 W/m²K

0.46 W/m²K

0.46 W/m²K

0.55 W/m²K

0.55 W/m²K

Number of louvres

1

1

2

2

3

3

Weight 39 kg 42 kg 54 kg 60 kg 69 kg 77 kg
Show more information
Request & 
Compare

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list

Add to comparison list / Remove from comparison list
Request Request Request Request Request Request

  • Thermally separated and insulated roof hood, particularly suitable for lift shafts and service shafts

  • Excellent heat transfer coefficient (U-value) of 0.41 - 0.55 W/m²K (DIN EN ISO 12567-2)

  • High-quality thermally separated louvre window on the inside

  • Installation on flat roofs and with 0° to 10° roof pitches

  • 100% weather protection

  • Approved construction product ready for installation on the roof, consisting of a curb, integrated motorised locking element with thermally separated aluminium profiles and weather protection lamella hood

  • Quick and easy integration into the building insulation

  • Ventilation and smoke extraction independent of wind direction and weather (secure against driving rain)

  • Prevented condensation thanks to base made of glass fibre reinforced plastic (GRP)

  • Integrated insect screen over the entire ventilation area

  • Low-noise direct current motor

Details of approval on request.

Instructions
117.36 KB
Product information
976.41 KB
Planning files
444.69 KB
1.19 MB
download-icon
588.68 KB
download-icon
955.35 KB
download-icon
1.06 MB
download-icon
2.26 MB
download-icon
2.26 MB
download-icon
2.32 MB
download-icon
2.68 MB
download-icon
BIM Data
512.00 KB
32.27 KB
32.62 KB
34.65 KB
35.19 KB
37.28 KB
37.73 KB
Tender documents
Generator
TF-DC-RJ-0,41-450x450-0,1
TF-DC-RJ-0,41-450x450x750-0,1
TF-DC-RJ-0,46-600x600-0,2
TF-DC-00-0,46-600x600x750-0,2
TF-DC-RJ-0,55-800x800-0,39
TF-DC-00-0,55-800x800x750-0,39